Descriptions:
NV-EVAC-FAE-EM648 is used for remote control NV-EVAC-FAE-EM648 system, allowing
remotely control for system voice message information and zones paging by users, it can
drive 8 zones and extended zones or groups by Microphone Extension
unit(NV-EVAC-FAE-EM648 ) to 64 zones, each can connect max 7 extension unit and every
extension keyboard have 8 zones
Features:
• One press to select zones, which is simple and intuitive.
• Parallel transmission; extend the transmission distance by CAT-5.
• Obvious system fault and module status indicator.
• Supporting zones or groups extension.
• With line audio input and adjustable input volume.
• Paging button mode and PTT mode are all available.
• Supporting redundant wiring.
• DC 24V Phantom Power supply.
Basic Functions:
• Microphone output level is adjusted.
• Ontrol priority right is available by NV-EVAC-FAE-RM647.
• Build-in Hi-Fi monitor speaker, with monitor output.
• One press into the paging status.
• External Headphone jack; can monitor or record paging voice.
Specification:
DC Supply | |
Voltage | 24V DC, ±20% |
Max Current | 0.1A (not including extended panel) |
Power Dissipation | 2.4W (not including extended panel) |
Performance Index | |
Balance Ipput | |
Distortion | <1%, 1KHz |
Frequency | 80Hz~16KHz |
Sensitivity | 500mV |
Impedance | 10KΩ |
Noise Ratio | >70dB |
Line Input | |
Distortion | <1% (RMS), 1KHz |
Frequency | 80Hz~16KHz |
Sensitivity | 775mV |
Output Impedance | 10KΩ |
S/N Ratio | >70dB |
Mic | |
Sensitivity | 5mV |
Output Impedance | 600Ω |
Mechanical Index | |
Size ( LxWxD ) | 256x52x149mm |
Weight | About 1.5Kg |
Installation | Desktop or 19 inch rack |
Color | Balck |
Environmental Requirement | |
Operation Temp | +5oC ~ + 40oC |
Storage Temp | -20oC ~ + 70oC |
Relative Temp | <95% no condensation |
Front Panel Connectors:
1. Goose Mic Socket.
2. Fault reset/Zone closed.
3. Full zone selection.
4. The status indication of main power supply in the system:
5. The status indication of backup DC power supply in the system:
6. Unusual status of any equipment or module in the system:
7. Testing button of the indicators on the panel: if this button is pressed, the indicators
on the panel are on from green, red, to yellow, which means it is in normal status.
8. The status of the goose mic:
▪ Green – Normal status of all the equipments and main power supply module in the system
▪ Yellow – Unusual status of any equipment or main power supply module in the system
▪ Off – Normal status of all the equipments and backup power supply module in the system.
▪ Yellow – Unusual status of any equipment or main power supply module in the system.
▪ Off – Normal status of all the equipments and modules.
▪ Yellow on or flashing – All the equipments or module of the system are in fault status.
▪ Off – Goose mic is normal.
▪ Yellow – There is fault in the goose mic.
9. Working status of the amplifiers in the system:
10. Zone working status indicator and selection button.
11. BGM control of the master unit:
12. Line input audio selection control button.
13. Goose mic and mic line input selection button.
14. Zone and zone function selection button.
15. Paging switch.
▪ Green – Normal status of all the equipments and main power supply module in the system
▪ Yellow – Unusual status of any equipment or main power supply module in the system
▪ Off – Normal status.
▪ Green – Working status.
▪ Yellow – Fault.